H.D.T. Heat Deflection Tester

QC-657B
H.D.T. Heat Deflection Tester

Send us an Inquiry

Description

A constant load is applied at the center of specimens with defined shape and dimensions, while the sample is heated at a rate of 2 °C/min. The heat deflection temperature (HDT) is recorded when a deformation of 0.254 mm is reached.

The QC-657B features a user-friendly touch-screen interface with guided operation, allowing for rapid setup. Built-in calculation functions enable quick conversion of specimen dimensions to the required test load, standardizing the HDT testing procedure and minimizing measurement errors.

Specimen holders and weight racks are manually adjustable. The system supports three independent test stations, each with dedicated monitoring of temperature and deflection. Upon test completion, the system automatically records the temperature, stops heating, and initiates water cooling.

Conform to Standards

  • ASTM D648
  • ASTM D1525
  • ISO 75-1
  • ISO 306
  • JIS K7191-1
  • JIS K7206

Industry

Plastic

Testing Video


Specifications


Model

QC-657B

Operating Temperature

Room temperature - 300℃

Temperature Control

2℃ increase per minute (adjustable)

Weights (Loads)

Loads provided per test station as follows:
0.1N×1, 0.2N×2, 0.5N×1, 1N×1, 2N×2, 5N×1, 10N×1

Deflection Measurement Range

0.001 - 3.000 mm

Support Span

100 mm, 64mm (101.6mm for options)

Support Form

R=3.0 mm (able to add the Vicat heat deflection test head)

Specimen Dimensions

ASTM L=5”(127 mm), d=1/2 ”(12.7 mm), b=1/4”( 6.35 mm)
ISO edge wise L=120mm, d=10mm, b=4mm
ISO flat wise L=80mm, d=10mm, b=4mm
※Specimen dimensions must be maintained within ±0.1 mm tolerance.

Number of Test Stations

Test stations:1,2,3 stations

Temperature Equalization Method

Circulating flow

Cooling Method

Water cooling

Power

Single phase, 220 VAC, 15A

Dimensions (WxDxH)

95 x 46 x 60 cm

Machine Weight

58 kg